This is an input on the panel that will shunt out a group of programmed inputs. The operation of the shunting process is as follows:

 

Action

Status

Outputs

Shunt Input closed (shunted)

Inputs within the Shunt Group are inactive

The ‘Follow Input’ output is live

Shunt Group Input triggered

No response

-

Shunt Input opened (unshunted)

-

The ‘Follow Input’ output clears. The ‘Shunt Fault’ output is live for 10 seconds.

After 10 seconds

Inputs in the Shunt Group are active

Indications off.

Shunt Input opened with an active detector (attempting to unshunt)

-

The ‘Follow Input’ output clears. The ‘Shunt Fault’ output pulses until the shunt is reset or the input fault clears.

Active input clears

-

The ‘Shunt Fault’ output is live for 10 seconds. PLEASE NOTE: This will not function correctly on an ATE pin

After 10 seconds

Inputs in the Shunt Group are active

Indications off.

Shunt Group Input triggered

Normal input response

(Note: depends upon the status of the Area in which the shunt is located).

 

 